Identity 4 of 4 pass
| Engine nameplate | Make, model and serial number match the listing | Pass |
| Alternator nameplate | Rating 500 kW, 400 V, 50 Hz, as listed | Pass |
| Year of build | Confirmed from nameplate and records | Pass |
| Purchase invoice | Purchase invoice sighted; title and finance checks recorded separately | Pass |
Condition 5 pass, 1 advisory
| Engine block and base frame | No cracks or impact damage found | Pass |
| Leaks | Minor oil weeping at rocker cover gasket | Advisory |
| Corrosion | Surface only, no structural corrosion | Pass |
| Turbocharger | No play on shaft, casing intact | Pass |
| Alternator windings | Insulation resistance 520 MΩ at 1,000 V DC, 2 min (calibrated tester) | Pass |
| Completeness | All listed parts present, including control panel | Pass |
Running test 5 pass, 1 advisory
| Start-up | Started on first attempt, idle stable | Pass |
| Load test | 45 min at 75% load (375 kW) on a resistive load bank | Pass |
| Lube oil pressure | 4.2 bar at 75% load (maker range 3.5–5.0 bar) | Pass |
| Exhaust temperatures | 385–440 °C; cylinder 4 at 440 °C, near the 450 °C maker limit | Advisory |
| Vibration and noise | No abnormal vibration or knocking | Pass |
| Voltage and frequency | 400 V ±1%, 50 Hz ±0.2 Hz during 25/50/75% load steps | Pass |
Hours and documents 4 of 4 pass
| Hour meter | 18,240 h, consistent with maintenance log | Pass |
| Last major overhaul | At 15,000 h, workshop report sighted | Pass |
| Class certificate | Sighted; valid at removal from vessel. Not a statement of current condition | Pass |
| Export documents | Commercial invoice and packing list prepared | Pass |
Photos and video
Real reports include the surveyor’s photographs and a video of the running test.
Tests not performed and limitations
Crankcase not opened; no oil analysis; parallel running with other sets not tested. Records were checked as presented by the seller. Acceptance standard: the transaction schedule agreed by both parties.
Loading advice
Drain fluids, preserve the engine for sea transport and ship on a flat rack. Estimated lifting weight 9.8 t. Remove and crate the control panel separately.
Surveyor’s declaration
I inspected this machine in person on the date shown. I have declared any connection to the buyer, the seller or the manufacturer, and my professional indemnity insurance details are recorded with this appointment.
Real reports carry the surveyor’s name, qualifications, signature, report date, serial-number photographs and instrument details.